JZ-RS

To prevent the spreading of smoke

Smoke protection dampers are used in ventilation plant rooms or in ducts to prevent smoke from spreading

  • Casing air leakage to EN 1751, class C
  • Low differential pressure and sound power level
  • Airflow direction is not critical
  • Available in standard sizes and many intermediate sizes


Optional equipment and accessories

  • Duct smoke detector RM-O-VS-D or RM-O-3-D
  • Installation subframe
  • Integration into the central BMS with TROXNETCOM

Application

Application

  • Smoke protection dampers of Type JZ-RS are used in ventilation plant rooms or in ducts to prevent smoke from spreading (according to the German guideline regarding fire protection requirements on ventilation systems, LüAR)
  • For the refurbishment of systems with regard to fire safety
  • Can be triggered by duct smoke detectors with general building inspectorate licence
  • Integration into the central BMS with TROXNETCOM

Special characteristics

  • Low differential pressure and sound power level
  • Aerofoil blades
  • Low-maintenance, robust construction
  • No parts with silicone
  • Available in standard sizes and many intermediate sizes
  • Closed cell side seals meet increased hygiene requirements

Classification

  • Building inspectorate licence Z-78.4-51 from the DIBt, Berlin, Germany
  • Casing air leakage to EN 1751, class C
  • Closed blade air leakage at a differential pressure of 40 Pa = 200 m³/h per m²
  • Long-term testing: 10,000 open/close cycles

Nominal sizes

  • Standard: B = 400 – 2000 mm (in increments of 200 mm), H = 345 – 1995 mm (in increments of 165 mm)
  • R20 sizes: B = 357 – 1998 mm (in R20 increments), H = 357 – 1998 mm (in R20er increments)

Description

Construction

  • Galvanised sheet steel, corner holes on both sides, brass bearings
  • G: Flange holes on both sides

Parts and characteristics

  • Frame
  • Blade
  • Spring return actuator
  • External linkage
  • Travel stop (angle section), side B
  • Side seal, side H

Attachments

  • Installation subframe ER
  • Duct smoke detector
  • TROXNETCOM

Construction features

  • Rectangular casing, welded, material thickness 1.25 mm
  • Blades, material thickness 1 mm, opposed action
  • Flanges on both sides, suitable for duct connection, either flange holes or corner holes
  • Spring return actuator on the 2nd blade (for all sizes)
  • Control input signal from the central BMS or TROXNETCOM
  • External linkage, robust and durable, consisting of the coupling rod and and horizontal arms
  • Blade shafts, Ø12 mm, with notch to indicate the blade position
  • Construction and materials comply with the EU directive and guidelines for use in potentially explosive atmospheres (ATEX)
  • Side seals between the regular blades and the frame
  • Travel stop (angle section) ensures tight closure of the top and bottom blades

Materials and surfaces

  • Casing, blades and travel stop (angle section) made of formed galvanised sheet steel; flanges on both sides with corner holes
  • Blade shafts, drive arm and external linkage made of galvanised steel
  • Side seal made of stainless steel
  • Brass bearings

Standards and guidelines

  • German 'Bau- und Prüfgrundsätze' [Principles of Construction and Testing], 2/84 edition
  • Maintenance standards DIN 31051 and EN 13305

Maintenance

  • Smoke protection dampers and duct smoke detectors must be maintained regularly and must be operational at all times
  • To maintain the normal function of the unit, or to re-instate its normal function, maintenance standards DIN 31051 and EN 13305 must be complied with
  • Smoke protection dampers must be maintained at least every 12 months
  • A maintenance report must be created; documents must be kept for reference
  • Maintenance-free as construction and materials are not subject to wear

Letöltések

termékinformáció

tanúsítványok

kezelési útmutatók

production {"X-Frame-Options"=>"SAMEORIGIN", "X-XSS-Protection"=>"1; mode=block", "X-Content-Type-Options"=>"nosniff", "X-Download-Options"=>"noopen", "X-Permitted-Cross-Domain-Policies"=>"none", "Referrer-Policy"=>"strict-origin-when-cross-origin", "Strict-Transport-Security"=>"max-age=31536000; includeSubDomains", "Content-Type"=>"text/html; charset=utf-8"}

Oldal megosztása

Oldal ajánlása

Oldal ajánlása, hivatkozás küldése e-mailben.

A *-gal jelölt mezők kitöltése kötelező.

Oldal megosztása

Köszönjük, hogy ajánlott minket!

Ajánlását elküldtük és hamarosan meg kell érkeznie.


Kapcsolat

Hol tartózkodik Ön?

Adja meg üzenetét és kérése típusát
Tel.: +36 (1)212-1211 | Fax: +36 (1)212-0735

Attachment (max. 10MB)

A *-gal jelölt mezők kitöltése kötelező.

Kapcsolat

Köszönjük üzenetét!

Az üzenet elküldve, hamarosan feldolgozzuk. Szervizigényekkel foglalkozó részlegünk a lehető leghamarabb felveszi Önnel a kapcsolatot.
Általános, termékekkel, szolgáltatásokkal kapcsolatos kérdéseivel a következő telefonszámokon is fordulhat hozzánk:
Tel.: +36 (1)212-1211 | Fax: +36 (1)212-0735

Kapcsolat

Hol tartózkodik Ön?

Adja meg üzenetét és kérése típusát
Tel.: +36 (1)212-1211 | Fax: +36 (1)212-0735

Attachment (max. 10MB)

A *-gal jelölt mezők kitöltése kötelező.

Kapcsolat

Köszönjük üzenetét!

Az üzenet elküldve, hamarosan feldolgozzuk. Szervizigényekkel foglalkozó részlegünk a lehető leghamarabb felveszi Önnel a kapcsolatot.
Általános, termékekkel, szolgáltatásokkal kapcsolatos kérdéseivel a következő telefonszámokon is fordulhat hozzánk:
Tel.: +36 (1)212-1211 | Fax: +36 (1)212-0735